Modular tank construction
Fire-Drop tanks with quick-assembly technology are modern bolted constructions designed for storing non-flammable liquids and bulk materials.
This innovative European manufacturing technology prevents direct contact between the metal walls and the stored substance, completely eliminating corrosion. The zinc coating on the exterior walls reliably protects the tank from atmospheric effects, significantly extending its service life.
Compact modular components can be packed into convenient crates on Euro pallets, simplifying transportation and allowing installation without heavy machinery.
Fire-Drop modular tank constructions: more convenient, more reliable, and more cost-effective than alternative solutions!
Applications of Modular Tanks
By Application
By Industry
-
01
Storage of fire-fighting water reserves

-
02
Storage of drinking and domestic water

-
03
Accumulation of hot water reserves (up to +70°C)

-
04
Storage of non-flammable technical liquids

-
05
Storage of liquid mineral fertilizers

-
06
Storage of bulk products (grain)

-
07
Manure collection tanks

-
08
Wastewater collection

-
09
Storage of treated water

Advantages of modular tanks
-
Protection against environmental impact
All tank components are made of galvanized steel, providing reliable protection against environmental influences and corrosion. Thanks to the zinc coating, the tanks not only look aesthetically pleasing but also have an extended service life. The zinc layer is applied in factory conditions using an electro-galvanizing process, with a coating thickness of up to 280 g/m².
-
Airtightness and leak-proofing
The tank’s interior is lined with a durable polymer membrane, ensuring complete airtightness and leak-proofing for over 30 years. The stored liquid does not come into contact with the metal, preventing internal corrosion and guaranteeing many years of reliable operation.
-
Operation at low temperatures
The tanks can be used in cold climates down to -60°C. Electric heaters of calculated capacity are installed inside the tank to maintain a positive temperature, while thermal insulation protects against freezing.
-
Factory manufacturing
Tank components are produced using high-precision equipment and undergo strict quality control. This ensures that all sheets and parts fit perfectly during assembly, maintaining the correct geometry of the structure. Painting in any RAL color is also carried out at the factory, ensuring a high-quality finish compared to on-site painting.
-
Delivery
We deliver tanks to any location in Russia using any type of transport. Metal structures are packed in standard containers and placed on standard pallets. Containers can be unloaded with a forklift. The compact size of the prefabricated components allows multiple tanks to be transported in a single vehicle, reducing transportation costs.
-
Tight installation deadlines
Tank installation is carried out in accordance with the work execution plan, without the use of heavy lifting equipment and without performing hot or high-altitude work. This allows tanks to be installed at operational facilities. Assembly can also be carried out in confined spaces and indoor environments..
Tank design
-
Test unit
Used to check the operability of pumps
-
Manhole
Installed on the roof and serves for visual inspection inside the tank
-
Overflow unit
Designed to protect the tank from overfilling beyond the set water level
-
Breather pipe
Designed to equalize air pressure inside the tank, preventing excessive pressure and vacuum formation, and preventing foreign objects from entering thanks to a metal mesh installed inside the pipe
-
Fill unit
Used to supply water into the tank and ensures stream break during filling
-
Communication unit
Designed to transfer water from one tank to an adjacent tank
-
Ladder with an inspection platform
Provides access to the manhole and maintenance of heating elements (HE)
-
Access hatch
Designed for entry into the tank for servicing
-
Drainage unit
Designed for complete emptying of the tank during maintenance operations.
-
Water intake unit
Used for draining the tank; connected to the suction line of the fire pump. Features an anti-vortex plate system that prevents liquid turbulence at maximum water intake speed
-
Heating Element (HE)
Ensures a positive liquid temperature during cold seasons
Advantages
of our design
-
Fill unit
The fill pipelines are made of polymer materials, which completely eliminates corrosion, and are located inside the tank, requiring no additional insulation. This contrasts with other manufacturers’ designs, where the fill pipeline is mounted on brackets outside the tank.
-
Control panel
The automation and level control panel is equipped with a controller featuring a digital display, showing information about the stored liquid volume, temperature, and the status of the instruments.
-
Energy-saving heating element
The energy-saving heating element features a built-in thermostat. The heating element is activated only when the liquid inside the tank reaches +5 oС.
-
Water intake unit
The water intake unit might be made from polymer material, reducing stress on the tank wall and completely eliminating corrosion.
Trusted by
Need help choosing the right equipment?
that I have read the agreement on the processing of personal data